{"product_id":"westinghouse-wgen20000-28000-peak-watt-and-20000-running-watt-home-backup-portable-generator-with-remote-electric-start","title":"Westinghouse WGen20000 28,000 Peak-Watt and 20,000 Running-Watt Home Backup Portable Generator with Remote Electric Start","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe \u003cstrong\u003eWestinghouse WGen20000 Portable Generator\u003c\/strong\u003e is an ultra-duty gasoline-powered generator engineered for large-home backup, demanding jobsites, workshops, farms, commercial properties, and emergency applications requiring substantial 120V and 240V power.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eDelivering up to \u003cstrong\u003e28,000 peak watts and 20,000 running watts\u003c\/strong\u003e, the WGen20000 provides enough capacity to operate multiple major appliances, essential household circuits, pumps, heating and cooling equipment, tools, lighting, and electronic devices when properly connected through approved transfer equipment.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAt the center of the generator is a heavy-duty \u003cstrong\u003e999cc Westinghouse V-Twin OHV engine\u003c\/strong\u003e with a cast-iron cylinder sleeve. The large-displacement engine is designed to deliver the torque and continuous output needed for demanding backup-power applications.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA substantial \u003cstrong\u003e17.2-gallon gasoline tank\u003c\/strong\u003e supports extended operation, while the integrated fuel gauge allows the operator to monitor remaining fuel without opening the tank. Westinghouse rates the generator for approximately \u003cstrong\u003e14 hours at 25% load and 8 hours at 50% load\u003c\/strong\u003e, although actual runtime varies with connected demand, engine condition, fuel quality, ambient temperature, and maintenance.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 includes remote and push-button electric starting, automatic choke, Smart Idle, GFCI-protected receptacles, copper alternator windings, a digital VFT data center, automatic low-oil shutdown, overload protection, reinforced handles, a wheel kit, and integrated lifting brackets.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIts 120\/240V outlet panel includes multiple 30-amp and 50-amp receptacles suitable for approved transfer-switch and interlock installations. This allows the generator to serve as a powerful temporary home-backup source when installed by a qualified electrician.\u003c\/p\u003e\n\u003ch2\u003e28,000 Peak Watts and 20,000 Running Watts\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 provides:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e28,000 peak watts\u003c\/li\u003e\n\u003cli\u003e20,000 continuous running watts\u003c\/li\u003e\n\u003cli\u003e120V and 240V output\u003c\/li\u003e\n\u003cli\u003eUp to 233.3 peak amps at 120V\u003c\/li\u003e\n\u003cli\u003eUp to 116.7 peak amps at 240V\u003c\/li\u003e\n\u003cli\u003eUp to 166.7 running amps at 120V\u003c\/li\u003e\n\u003cli\u003eUp to 83.3 running amps at 240V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003ePeak wattage represents the temporary surge available when appliances and equipment with motors, compressors, or pumps first start.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eRunning wattage represents the continuous power available after the equipment has started and reached normal operation.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eHigh-starting-demand equipment may include:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eCentral air-conditioning systems\u003c\/li\u003e\n\u003cli\u003eWell pumps\u003c\/li\u003e\n\u003cli\u003eSump pumps\u003c\/li\u003e\n\u003cli\u003eRefrigerators\u003c\/li\u003e\n\u003cli\u003eFreezers\u003c\/li\u003e\n\u003cli\u003eAir compressors\u003c\/li\u003e\n\u003cli\u003eFurnaces\u003c\/li\u003e\n\u003cli\u003eWorkshop machinery\u003c\/li\u003e\n\u003cli\u003eConstruction tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe total continuous load must remain within the generator’s 20,000-watt running capacity. Starting demands must also be calculated so that simultaneous motor startups do not exceed the available 28,000-watt surge output.\u003c\/p\u003e\n\u003ch2\u003eLarge-Home Backup Capability\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 is designed for larger backup-power requirements than ordinary residential portable generators.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eDepending on the electrical system and load-management plan, it may support combinations of:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eCentral air-conditioning equipment\u003c\/li\u003e\n\u003cli\u003eRefrigerator and freezer\u003c\/li\u003e\n\u003cli\u003eFurnace or boiler controls\u003c\/li\u003e\n\u003cli\u003eSump pump\u003c\/li\u003e\n\u003cli\u003eWell pump\u003c\/li\u003e\n\u003cli\u003eLighting circuits\u003c\/li\u003e\n\u003cli\u003eGarage-door opener\u003c\/li\u003e\n\u003cli\u003eInternet and communications equipment\u003c\/li\u003e\n\u003cli\u003eTelevision and entertainment equipment\u003c\/li\u003e\n\u003cli\u003eSelected kitchen appliances\u003c\/li\u003e\n\u003cli\u003eMicrowave\u003c\/li\u003e\n\u003cli\u003eWashing machine\u003c\/li\u003e\n\u003cli\u003eHome-office equipment\u003c\/li\u003e\n\u003cli\u003eSecurity systems\u003c\/li\u003e\n\u003cli\u003eMedical-support equipment within verified electrical limits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator should not automatically be assumed capable of powering every circuit in a home at the same time. Electric water heaters, electric ranges, clothes dryers, large HVAC systems, and high-amperage pumps can consume substantial portions of the available output.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA qualified electrician should calculate both running and starting loads before determining which household circuits can be supported.\u003c\/p\u003e\n\u003ch2\u003eTransfer-Switch and Interlock Ready\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 includes both 30-amp and 50-amp 120\/240V receptacles for connection to compatible transfer equipment.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIts transfer-switch-ready outlet configuration includes:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eTwo 120\/240V L14-30R 30A receptacles\u003c\/li\u003e\n\u003cli\u003eTwo 120\/240V 14-50R 50A receptacles\u003c\/li\u003e\n\u003cli\u003eOne 120V L5-30R 30A receptacle\u003c\/li\u003e\n\u003cli\u003eFour 120V 5-20R household outlets arranged as two duplex receptacles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe 50-amp 14-50R outlets are especially useful for connecting the generator to a properly installed home power-inlet box, manual transfer switch, or approved interlock system.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 must never be connected to household wiring through an improvised cord or by plugging the generator into a standard wall outlet. This dangerous practice can back-feed utility lines and expose utility workers, occupants, and equipment to serious electrical hazards.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA licensed electrician should install and inspect all permanent home-backup connections.\u003c\/p\u003e\n\u003ch2\u003e999cc Westinghouse V-Twin OHV Engine\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator is powered by a \u003cstrong\u003e999cc Westinghouse V-Twin overhead-valve engine\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe V-Twin configuration uses two cylinders to produce the high torque required for continuous 20,000-watt output. Compared with smaller single-cylinder generator engines, the larger V-Twin design is better suited to demanding loads and extended operation.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe engine includes:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eCast-iron cylinder sleeve\u003c\/li\u003e\n\u003cli\u003eAutomatic choke\u003c\/li\u003e\n\u003cli\u003eRemote starting\u003c\/li\u003e\n\u003cli\u003ePush-button electric starting\u003c\/li\u003e\n\u003cli\u003eSmart Idle\u003c\/li\u003e\n\u003cli\u003eAutomatic low-oil shutdown\u003c\/li\u003e\n\u003cli\u003eReplaceable air filter\u003c\/li\u003e\n\u003cli\u003eServiceable spark plugs\u003c\/li\u003e\n\u003cli\u003eLarge-capacity lubrication system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe cast-iron sleeve improves durability and wear resistance during extended operation.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eEngine maintenance remains necessary and includes regular oil changes, air-filter inspection, spark-plug servicing, cooling-system cleaning, fuel-system maintenance, and battery care.\u003c\/p\u003e\n\u003ch2\u003eRemote and Push-Button Electric Start\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 supports:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eWireless remote start\u003c\/li\u003e\n\u003cli\u003ePush-button electric start\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe included remote allows the operator to start and stop the generator from a convenient distance, provided the unit has already been positioned outdoors, fueled, inspected, connected, and placed in the correct operating mode.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003ePush-button electric start allows the generator to be started directly from the control panel without manually pulling a recoil cord.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe starting battery is included. Battery condition should be checked regularly, especially when the generator is stored for extended periods.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA compatible battery maintainer may be useful for emergency-backup generators that remain unused for several months.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Choke\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe automatic choke system simplifies starting by automatically controlling the engine’s air-and-fuel mixture during startup.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis reduces the need for manual choke adjustment and makes both remote and push-button starting more convenient.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe choke system should still be inspected and maintained as part of routine engine service.\u003c\/p\u003e\n\u003ch2\u003eSmart Idle System\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eSmart Idle automatically lowers engine speed when electrical demand is reduced.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis can provide several benefits:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eReduced gasoline consumption\u003c\/li\u003e\n\u003cli\u003eLower operating noise\u003c\/li\u003e\n\u003cli\u003eReduced unnecessary engine wear\u003c\/li\u003e\n\u003cli\u003eImproved efficiency during light-load operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eWhen electrical demand rises, the engine returns to the speed required to support the connected load.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eSmart Idle may need to be disabled when starting equipment with a large surge requirement. The operator should follow the instructions in the generator manual and the requirements of the connected equipment.\u003c\/p\u003e\n\u003ch2\u003e17.2-Gallon Fuel Tank\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator includes a large \u003cstrong\u003e17.2-gallon gasoline tank\u003c\/strong\u003e, equivalent to approximately 65 liters.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe tank’s capacity allows extended operation without frequent refueling, an important benefit during prolonged utility outages and demanding jobsite use.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAn integrated fuel gauge helps the operator monitor fuel level.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eWestinghouse’s current specification table lists approximately:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e14 hours of runtime at 25% load\u003c\/li\u003e\n\u003cli\u003e8 hours of runtime at 50% load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eSome Westinghouse promotional text references longer figures under different operating conditions. Runtime should therefore be presented using the load-specific specification ratings rather than as a guaranteed operating duration.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eActual runtime depends on:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eConnected electrical load\u003c\/li\u003e\n\u003cli\u003eSmart Idle operation\u003c\/li\u003e\n\u003cli\u003eFuel quality\u003c\/li\u003e\n\u003cli\u003eEngine condition\u003c\/li\u003e\n\u003cli\u003eAmbient temperature\u003c\/li\u003e\n\u003cli\u003eAltitude\u003c\/li\u003e\n\u003cli\u003eMaintenance\u003c\/li\u003e\n\u003cli\u003eFrequency of heavy startup loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe engine must be shut down and allowed to cool before gasoline is added.\u003c\/p\u003e\n\u003ch2\u003eClean Copper Alternator Windings\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 uses copper alternator windings.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eCopper provides efficient electrical conductivity and helps the alternator operate with reduced resistance and heat buildup compared with lower-grade winding materials.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eWestinghouse states that the copper windings help the generator produce cleaner power, operate cooler, and provide longer service life.\u003c\/p\u003e\n\u003ch2\u003eLess Than 5% Total Harmonic Distortion\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eWestinghouse rates the generator at \u003cstrong\u003e5% or less total harmonic distortion\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis is relatively clean output for a large conventional portable generator and makes the WGen20000 suitable for many household electronics, including:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eComputers\u003c\/li\u003e\n\u003cli\u003eTelevisions\u003c\/li\u003e\n\u003cli\u003ePhone chargers\u003c\/li\u003e\n\u003cli\u003eNetworking equipment\u003c\/li\u003e\n\u003cli\u003eHome-office devices\u003c\/li\u003e\n\u003cli\u003eEntertainment systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIt is still a conventional generator rather than an inverter generator. Users of highly sensitive medical, laboratory, communications, or industrial equipment should verify the electrical requirements of those devices before connection.\u003c\/p\u003e\n\u003ch2\u003eVFT Digital Data Center\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe control panel includes a digital VFT data center that displays:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eElectrical frequency\u003c\/li\u003e\n\u003cli\u003eLifetime running hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eVoltage monitoring helps confirm that the generator is producing the expected electrical output.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eFrequency monitoring helps the operator verify stable 60 Hz operation.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe hour meter helps track maintenance intervals for:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eEngine-oil changes\u003c\/li\u003e\n\u003cli\u003eAir-filter service\u003c\/li\u003e\n\u003cli\u003eSpark-plug inspection\u003c\/li\u003e\n\u003cli\u003eFuel-system maintenance\u003c\/li\u003e\n\u003cli\u003eGeneral scheduled service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eMaintenance should be performed based on the manual’s operating-hour intervals rather than calendar time alone.\u003c\/p\u003e\n\u003ch2\u003eGFCI-Protected Household Outlets\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe four standard 120V household outlets are GFCI protected.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eGround-fault circuit-interrupter protection helps disconnect output if an imbalance indicates that electricity may be flowing through an unintended path.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eGFCI protection is especially valuable on jobsites, outdoors, and in other locations where moisture or grounded surfaces may be present.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe outlets also include rubber covers to help protect them from dirt and debris when not in use.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eOutlet covers do not make the generator weatherproof. The unit should not be operated in rain, standing water, or unsafe wet conditions.\u003c\/p\u003e\n\u003ch2\u003eComplete Outlet Configuration\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 includes:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eTwo duplex 120V 5-20R receptacles, providing four household outlets\u003c\/li\u003e\n\u003cli\u003eOne 120V L5-30R 30A twist-lock receptacle\u003c\/li\u003e\n\u003cli\u003eTwo 120\/240V L14-30R 30A twist-lock receptacles\u003c\/li\u003e\n\u003cli\u003eTwo 120\/240V 14-50R 50A receptacles\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis large outlet selection allows the generator to support:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eHome transfer equipment\u003c\/li\u003e\n\u003cli\u003eHigh-amperage tools\u003c\/li\u003e\n\u003cli\u003eWorkshop equipment\u003c\/li\u003e\n\u003cli\u003eConstruction equipment\u003c\/li\u003e\n\u003cli\u003ePumps\u003c\/li\u003e\n\u003cli\u003eTemporary power distribution\u003c\/li\u003e\n\u003cli\u003eStandard 120V appliances\u003c\/li\u003e\n\u003cli\u003eCompatible 120\/240V electrical loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAll cords, adapters, transfer equipment, and distribution devices must be rated for the voltage and amperage being supplied.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Low-Oil Shutdown\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe engine includes automatic low-oil shutdown.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIf the oil level falls below a safe operating range, the engine shuts down to help prevent internal damage.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis feature does not replace regular oil checks.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator should be positioned on a firm and level surface when checking oil or operating the engine. An uneven position can affect lubrication and oil-sensor accuracy.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eWestinghouse specifies:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eOil capacity: 77.8 fluid ounces\u003c\/li\u003e\n\u003cli\u003eApproximate oil capacity: 2.3 quarts\u003c\/li\u003e\n\u003cli\u003eRecommended oil type: 10W-30\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eOil grade may need to be adjusted for extreme ambient temperatures according to the owner’s manual.\u003c\/p\u003e\n\u003ch2\u003eOverload Protection\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIntegrated overload protection helps protect the generator if connected electrical demand exceeds its safe output.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIf an overload occurs:\u003c\/p\u003e\n\u003col start=\"1\" data-spread=\"false\"\u003e\n\u003cli\u003eDisconnect or switch off the connected equipment.\u003c\/li\u003e\n\u003cli\u003eCalculate total running wattage.\u003c\/li\u003e\n\u003cli\u003eIdentify appliances with large startup demand.\u003c\/li\u003e\n\u003cli\u003eReset the affected breaker.\u003c\/li\u003e\n\u003cli\u003eRestart or reconnect loads individually.\u003c\/li\u003e\n\u003cli\u003eLeave sufficient unused capacity for motor startup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp class=\"isSelectedEnd\"\u003eRepeated breaker trips indicate that the load is too high, there is a short circuit, or connected equipment has a fault.\u003c\/p\u003e\n\u003ch2\u003eBonded-Neutral Grounding System\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 uses a bonded-neutral grounding configuration.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eGrounding requirements can vary depending on whether the generator is used as a separately derived system, connected through transfer equipment, or used as a portable supply.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA qualified electrician should determine whether the neutral-ground bond is appropriate for the intended installation and whether transfer equipment switches the neutral conductor.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIncorrect neutral and grounding arrangements can create shock hazards or cause GFCI and protective devices to operate improperly.\u003c\/p\u003e\n\u003ch2\u003eHeavy-Duty Steel Frame\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator is built around a rugged steel frame designed to protect the engine, alternator, fuel tank, and control components.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe frame includes reinforced handles with quick-release pins, allowing the handles to be installed or removed for transport and storage.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe open-frame design provides access for cooling and service, but it also produces more operating noise than an enclosed inverter generator.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator must never be covered while operating.\u003c\/p\u003e\n\u003ch2\u003eIntegrated Lift Brackets\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eBuilt-in lift brackets provide attachment points for suitable lifting equipment.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eBecause the generator weighs approximately \u003cstrong\u003e540 pounds dry\u003c\/strong\u003e, the lift brackets are important for loading, unloading, and positioning the unit at jobsites or commercial properties.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eOnly lifting equipment rated for the complete generator weight should be used.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator should never be lifted while operating, hot, leaking fuel, or connected to electrical loads.\u003c\/p\u003e\n\u003ch2\u003eWheel and Handle Kit\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA heavy-duty wheel and handle kit is included.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe wheels and reinforced handles make it possible to reposition the generator across driveways, garages, jobsites, and other firm surfaces.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAt 540 pounds without fuel, the generator remains extremely heavy. Multiple people, lifting machinery, ramps, or powered equipment may be required for safe transportation.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA full 17.2-gallon tank can add more than 100 pounds to the generator’s operating weight.\u003c\/p\u003e\n\u003ch2\u003eOperating Noise\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eWestinghouse lists the noise level at approximately \u003cstrong\u003e74 dBA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eActual sound levels depend on:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eConnected load\u003c\/li\u003e\n\u003cli\u003eSmart Idle status\u003c\/li\u003e\n\u003cli\u003eEngine speed\u003c\/li\u003e\n\u003cli\u003eDistance from the generator\u003c\/li\u003e\n\u003cli\u003eNearby buildings and walls\u003c\/li\u003e\n\u003cli\u003eGround surface\u003c\/li\u003e\n\u003cli\u003eMeasurement method\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 is an open-frame ultra-duty generator and should not be described as a quiet or super-quiet model.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eHearing protection may be appropriate for operators working near the generator for extended periods.\u003c\/p\u003e\n\u003ch2\u003eHome Backup Installation\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eFor home-backup use, a typical installation may require:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eApproved exterior power-inlet box\u003c\/li\u003e\n\u003cli\u003eManual transfer switch or interlock kit\u003c\/li\u003e\n\u003cli\u003eProperly rated generator cord\u003c\/li\u003e\n\u003cli\u003eCorrect breaker sizing\u003c\/li\u003e\n\u003cli\u003eLoad-management plan\u003c\/li\u003e\n\u003cli\u003eGrounding and bonding assessment\u003c\/li\u003e\n\u003cli\u003ePermits or inspections where required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAll installation work should comply with applicable electrical codes and utility requirements.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eA qualified electrician should verify that the connected inlet, cord, breaker, and transfer equipment can safely handle the intended amperage.\u003c\/p\u003e\n\u003ch2\u003eSuitable Jobsite Applications\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 can support demanding commercial and construction equipment, including compatible:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eAir compressors\u003c\/li\u003e\n\u003cli\u003eConcrete tools\u003c\/li\u003e\n\u003cli\u003eWelders within output limits\u003c\/li\u003e\n\u003cli\u003ePumps\u003c\/li\u003e\n\u003cli\u003eSaws\u003c\/li\u003e\n\u003cli\u003eLighting systems\u003c\/li\u003e\n\u003cli\u003eTemporary power panels\u003c\/li\u003e\n\u003cli\u003eTrailers\u003c\/li\u003e\n\u003cli\u003eMobile workshops\u003c\/li\u003e\n\u003cli\u003eMultiple handheld tools\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eIndividual tool startup and running requirements must be checked before use.\u003c\/p\u003e\n\u003ch2\u003eRoutine Maintenance\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eRoutine maintenance should include:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eChecking engine oil before every use\u003c\/li\u003e\n\u003cli\u003eChanging engine oil at scheduled intervals\u003c\/li\u003e\n\u003cli\u003eInspecting and cleaning the air filter\u003c\/li\u003e\n\u003cli\u003eReplacing air-filter elements when necessary\u003c\/li\u003e\n\u003cli\u003eInspecting and replacing spark plugs\u003c\/li\u003e\n\u003cli\u003eMaintaining the electric-start battery\u003c\/li\u003e\n\u003cli\u003eChecking fuel lines and fittings\u003c\/li\u003e\n\u003cli\u003eInspecting the fuel tank and cap\u003c\/li\u003e\n\u003cli\u003eCleaning engine cooling areas\u003c\/li\u003e\n\u003cli\u003eInspecting electrical outlets and breakers\u003c\/li\u003e\n\u003cli\u003eTesting the GFCI outlets\u003c\/li\u003e\n\u003cli\u003eChecking wheel and handle hardware\u003c\/li\u003e\n\u003cli\u003eInspecting lift brackets\u003c\/li\u003e\n\u003cli\u003eMonitoring voltage, frequency, and running hours\u003c\/li\u003e\n\u003cli\u003eStabilizing or draining gasoline before long-term storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eOnly fresh gasoline meeting Westinghouse fuel requirements should be used.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe generator should be allowed to cool before refueling, transportation, cleaning, or storage.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWestinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWGen20000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e20001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e850011336601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUltra-Duty Home Backup Portable Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Type\u003c\/td\u003e\n\u003ctd\u003eGasoline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output\u003c\/td\u003e\n\u003ctd\u003e28,000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning Output\u003c\/td\u003e\n\u003ctd\u003e20,000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Amperage at 120V\u003c\/td\u003e\n\u003ctd\u003e233.3 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Amperage at 240V\u003c\/td\u003e\n\u003ctd\u003e116.7 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning Amperage at 120V\u003c\/td\u003e\n\u003ctd\u003e166.7 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRunning Amperage at 240V\u003c\/td\u003e\n\u003ctd\u003e83.3 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e120V\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Harmonic Distortion\u003c\/td\u003e\n\u003ctd\u003e5% or Less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine\u003c\/td\u003e\n\u003ctd\u003eWestinghouse V-Twin OHV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine Displacement\u003c\/td\u003e\n\u003ctd\u003e999cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinder Sleeve\u003c\/td\u003e\n\u003ctd\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting System\u003c\/td\u003e\n\u003ctd\u003eRemote and Push-Button Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Battery\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChoke\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmart Idle\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel-Tank Capacity\u003c\/td\u003e\n\u003ctd\u003e17.2 Gallons \/ 65 Liters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Gauge\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at 25% Load\u003c\/td\u003e\n\u003ctd\u003eApproximately 14 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRuntime at 50% Load\u003c\/td\u003e\n\u003ctd\u003eApproximately 8 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Capacity\u003c\/td\u003e\n\u003ctd\u003e77.8 Fluid Ounces \/ 2.3 Quarts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Oil\u003c\/td\u003e\n\u003ctd\u003e10W-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Low-Oil Shutdown\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternator Windings\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrounding Configuration\u003c\/td\u003e\n\u003ctd\u003eBonded Neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGFCI Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet Covers\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousehold Outlets\u003c\/td\u003e\n\u003ctd\u003eFour 120V 5-20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120V 30A Outlet\u003c\/td\u003e\n\u003ctd\u003eOne L5-30R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120\/240V 30A Outlets\u003c\/td\u003e\n\u003ctd\u003eTwo L14-30R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120\/240V 50A Outlets\u003c\/td\u003e\n\u003ctd\u003eTwo 14-50R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer-Switch Ready\u003c\/td\u003e\n\u003ctd\u003eYes, Up to 50A Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRV Ready\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Meter\u003c\/td\u003e\n\u003ctd\u003eVoltage, Frequency and Lifetime Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003eApproximately 74 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame\u003c\/td\u003e\n\u003ctd\u003eHeavy-Duty Open Steel Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLift Brackets\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWheel and Handle Kit\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEPA Compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCARB Compliant\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon-Monoxide Sensor\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e38 × 35 × 40.4 Inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDry Weight\u003c\/td\u003e\n\u003ctd\u003e540 Pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e573 Pounds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidential Warranty\u003c\/td\u003e\n\u003ctd\u003e3-Year Limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Warranty\u003c\/td\u003e\n\u003ctd\u003e1-Year Limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"isSelectedEnd\"\u003eWestinghouse’s official specification table confirms the model number, output ratings, engine, runtime, fuel capacity, outlets, noise level, weight, dimensions, compliance status, and warranty coverage.\u003c\/p\u003e\n\u003ch2\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eWestinghouse WGen20000 portable generator\u003c\/li\u003e\n\u003cli\u003e999cc Westinghouse V-Twin OHV engine\u003c\/li\u003e\n\u003cli\u003e17.2-gallon gasoline fuel tank\u003c\/li\u003e\n\u003cli\u003eElectric-start battery\u003c\/li\u003e\n\u003cli\u003eWireless remote-start key fob\u003c\/li\u003e\n\u003cli\u003eHeavy-duty wheel kit\u003c\/li\u003e\n\u003cli\u003eReinforced steel handles\u003c\/li\u003e\n\u003cli\u003eQuick-release handle pins\u003c\/li\u003e\n\u003cli\u003eIntegrated lift brackets\u003c\/li\u003e\n\u003cli\u003eOil bottle\u003c\/li\u003e\n\u003cli\u003eOil funnel\u003c\/li\u003e\n\u003cli\u003eSpark-plug wrench\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eOwner’s manual\u003c\/li\u003e\n\u003cli\u003eWarranty documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eGenerator cord, transfer switch, interlock kit, home power-inlet box, fuel, and permanent electrical-installation components are normally sold separately.\u003c\/p\u003e\n\u003ch2\u003eAccessories Sold Separately\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e50-amp generator power cord\u003c\/li\u003e\n\u003cli\u003e30-amp generator power cord\u003c\/li\u003e\n\u003cli\u003eExterior power-inlet box\u003c\/li\u003e\n\u003cli\u003eManual transfer switch\u003c\/li\u003e\n\u003cli\u003eApproved generator interlock kit\u003c\/li\u003e\n\u003cli\u003eTemporary power-distribution equipment\u003c\/li\u003e\n\u003cli\u003eHeavy-duty outdoor extension cords\u003c\/li\u003e\n\u003cli\u003eGenerator weather cover\u003c\/li\u003e\n\u003cli\u003eBattery maintainer\u003c\/li\u003e\n\u003cli\u003eReplacement starting battery\u003c\/li\u003e\n\u003cli\u003eFuel stabilizer\u003c\/li\u003e\n\u003cli\u003eReplacement air filter\u003c\/li\u003e\n\u003cli\u003eReplacement spark plugs\u003c\/li\u003e\n\u003cli\u003eEngine oil\u003c\/li\u003e\n\u003cli\u003eOil-drain accessories\u003c\/li\u003e\n\u003cli\u003eSurge-protection equipment\u003c\/li\u003e\n\u003cli\u003eHearing protection\u003c\/li\u003e\n\u003cli\u003eApproved outdoor operating shelter designed for portable generators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"isSelectedEnd\"\u003eAccessory ratings must match the generator’s voltage, amperage, receptacle type, and intended application.\u003c\/p\u003e\n\u003ch2\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eLarge-home emergency backup\u003c\/li\u003e\n\u003cli\u003eCentral air-conditioning support within calculated limits\u003c\/li\u003e\n\u003cli\u003eRefrigerator and freezer backup\u003c\/li\u003e\n\u003cli\u003eWell-pump operation\u003c\/li\u003e\n\u003cli\u003eSump-pump operation\u003c\/li\u003e\n\u003cli\u003eFurnace and boiler support\u003c\/li\u003e\n\u003cli\u003eEssential household circuits\u003c\/li\u003e\n\u003cli\u003eCommercial facilities\u003c\/li\u003e\n\u003cli\u003eConstruction jobsites\u003c\/li\u003e\n\u003cli\u003eFarms and ranches\u003c\/li\u003e\n\u003cli\u003eWorkshops\u003c\/li\u003e\n\u003cli\u003eTemporary power distribution\u003c\/li\u003e\n\u003cli\u003eHigh-demand power tools\u003c\/li\u003e\n\u003cli\u003eMobile service operations\u003c\/li\u003e\n\u003cli\u003eEmergency-response power\u003c\/li\u003e\n\u003cli\u003eProperty-maintenance operations\u003c\/li\u003e\n\u003cli\u003eUsers requiring 30A and 50A 120\/240V connections\u003c\/li\u003e\n\u003cli\u003eApplications needing up to 20,000 continuous watts\u003c\/li\u003e\n\u003cli\u003eUsers requiring remote electric starting\u003c\/li\u003e\n\u003cli\u003eLocations requiring long gasoline runtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eImportant Safety Information\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThis generator must only be operated outdoors, far away from occupied buildings, doors, windows, vents, garages, basements, and other enclosed or partially enclosed areas.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eThe WGen20000 specification lists \u003cstrong\u003eno integrated carbon-monoxide sensor\u003c\/strong\u003e, making correct outdoor placement and working carbon-monoxide alarms inside occupied buildings especially important.\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003eNever operate the generator:\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003eInside a home\u003c\/li\u003e\n\u003cli\u003eInside a garage\u003c\/li\u003e\n\u003cli\u003eInside a shed\u003c\/li\u003e\n\u003cli\u003eIn a basement\u003c\/li\u003e\n\u003cli\u003eUnder an enclosed porch\u003c\/li\u003e\n\u003cli\u003eInside a trailer\u003c\/li\u003e\n\u003cli\u003eNear open doors or windows\u003c\/li\u003e\n\u003cli\u003eIn any location where exhaust could enter an occupied building\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe generator must never be connected directly to a home through a standard wall outlet. A transfer switch or approved interlock system must be professionally installed to prevent dangerous electrical back-feed.\u003c\/p\u003e","brand":"Northroot","offers":[{"title":"Default Title","offer_id":43743217483866,"sku":null,"price":649.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0751\/0366\/6266\/files\/main-image.webp?v=1785187621","url":"https:\/\/checkout.northroot.shop\/products\/westinghouse-wgen20000-28000-peak-watt-and-20000-running-watt-home-backup-portable-generator-with-remote-electric-start","provider":"Northroot","version":"1.0","type":"link"}