{"product_id":"predator-13000-watt-tri-fuel-portable-generator-with-remote-start-and-co-secure-technology","title":"PREDATOR 13,000-Watt Tri-Fuel Portable Generator with Remote Start and CO SECURE Technology","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1bw7wp4\" data-start=\"95\" data-end=\"117\"\u003eroduct Description\u003c\/h2\u003e\n\u003cp data-start=\"119\" data-end=\"353\"\u003eThe PREDATOR 13,000-Watt Tri-Fuel Portable Generator is a high-output backup power solution designed for home emergencies, jobsites, outdoor events, workshops, and other applications requiring dependable 120V or 240V electrical power.\u003c\/p\u003e\n\u003cp data-start=\"355\" data-end=\"764\"\u003eIts tri-fuel system allows the generator to operate on gasoline, liquid propane, or natural gas. This gives the operator flexibility to select a fuel source based on availability, storage requirements, expected runtime, and the type of installation. A clearly marked fuel-selector switch makes it easy to change between gasoline, propane, and natural-gas operating modes.\u003c\/p\u003e\n\u003cp data-start=\"766\" data-end=\"1080\"\u003eThe generator is powered by a 458cc PREDATOR four-stroke engine. When operating on gasoline, it produces up to 13,000 starting watts and 10,000 running watts. Output is reduced when propane or natural gas is used because gaseous fuels contain less usable energy than gasoline.\u003c\/p\u003e\n\u003cp data-start=\"1082\" data-end=\"1359\"\u003eThe combination of high output, multiple 120V and 120\/240V receptacles, remote starting, automatic idle-down, digital monitoring, and CO SECURE protection makes this model suitable for users who need a versatile portable generator capable of supporting larger electrical loads.\u003c\/p\u003e\n\u003ch2 data-section-id=\"jxigq0\" data-start=\"1361\" data-end=\"1382\"\u003eTri-Fuel Operation\u003c\/h2\u003e\n\u003cp data-start=\"1384\" data-end=\"1438\"\u003eThe generator can operate using three different fuels:\u003c\/p\u003e\n\u003cul data-start=\"1440\" data-end=\"1481\"\u003e\n\u003cli data-section-id=\"czkw7w\" data-start=\"1440\" data-end=\"1450\"\u003eGasoline\u003c\/li\u003e\n\u003cli data-section-id=\"4qopar\" data-start=\"1451\" data-end=\"1467\"\u003eLiquid propane\u003c\/li\u003e\n\u003cli data-section-id=\"akqxgs\" data-start=\"1468\" data-end=\"1481\"\u003eNatural gas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1483\" data-end=\"1698\"\u003eGasoline provides the generator’s highest available starting and running output. It is useful when maximum power is required for appliances, tools, pumps, compressors, and other equipment with high starting demands.\u003c\/p\u003e\n\u003cp data-start=\"1700\" data-end=\"1913\"\u003ePropane provides easier long-term fuel storage and produces fewer fuel-system deposits than gasoline. It is supplied from a compatible propane cylinder through the generator’s fuel connection and regulator system.\u003c\/p\u003e\n\u003cp data-start=\"1915\" data-end=\"2173\"\u003eNatural gas allows the generator to connect to a properly sized household natural-gas supply. It can be particularly useful for extended backup operation because it does not require repeatedly filling the onboard gasoline tank or replacing propane cylinders.\u003c\/p\u003e\n\u003cp data-start=\"2175\" data-end=\"2542\"\u003eNatural-gas installation must provide the pressure and flow required by the generator. Harbor Freight specifies that the natural-gas hose must be more than 20 feet long, and the 25-foot natural-gas hose is sold separately. Gas connections and home-backup installations should be completed or inspected by qualified professionals.\u003c\/p\u003e\n\u003cp data-start=\"2544\" data-end=\"2783\"\u003eThe fuel-selector switch includes settings for gasoline, propane, natural gas, and off\/storage. Moving the selector to the off\/storage position shuts off fuel flow when the generator is not being used.\u003c\/p\u003e\n\u003ch2 data-section-id=\"xac33w\" data-start=\"2785\" data-end=\"2813\"\u003ePower Output by Fuel Type\u003c\/h2\u003e\n\u003cp data-start=\"2815\" data-end=\"2890\"\u003eThe generator’s available electrical output depends on the fuel being used.\u003c\/p\u003e\n\u003cp data-start=\"2892\" data-end=\"2908\"\u003eGasoline Output:\u003c\/p\u003e\n\u003cul data-start=\"2910\" data-end=\"2989\"\u003e\n\u003cli data-section-id=\"1trm0u6\" data-start=\"2910\" data-end=\"2948\"\u003eMaximum starting power: 13,000 watts\u003c\/li\u003e\n\u003cli data-section-id=\"fygven\" data-start=\"2949\" data-end=\"2989\"\u003eContinuous running power: 10,000 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2991\" data-end=\"3006\"\u003ePropane Output:\u003c\/p\u003e\n\u003cul data-start=\"3008\" data-end=\"3086\"\u003e\n\u003cli data-section-id=\"4gggsf\" data-start=\"3008\" data-end=\"3046\"\u003eMaximum starting power: 12,000 watts\u003c\/li\u003e\n\u003cli data-section-id=\"16c2nba\" data-start=\"3047\" data-end=\"3086\"\u003eContinuous running power: 9,100 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3088\" data-end=\"3107\"\u003eNatural Gas Output:\u003c\/p\u003e\n\u003cul data-start=\"3109\" data-end=\"3187\"\u003e\n\u003cli data-section-id=\"1mwfp9\" data-start=\"3109\" data-end=\"3147\"\u003eMaximum starting power: 10,000 watts\u003c\/li\u003e\n\u003cli data-section-id=\"1up2hq9\" data-start=\"3148\" data-end=\"3187\"\u003eContinuous running power: 7,800 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3189\" data-end=\"3458\"\u003eThese ratings show why connected equipment must be calculated using the output available for the selected fuel. A load that operates correctly on gasoline may exceed the generator’s capacity when the unit is changed to natural gas.\u003c\/p\u003e\n\u003cp data-start=\"3460\" data-end=\"3685\"\u003eStarting wattage is the temporary surge power available for appliances and tools that require extra electricity during startup. Running wattage represents the continuous power available after connected equipment is operating.\u003c\/p\u003e\n\u003cp data-start=\"3687\" data-end=\"3939\"\u003eThe total running load should remain below the generator’s running-watt rating. Starting requirements must also be considered when operating refrigerators, freezers, air-conditioning systems, well pumps, sump pumps, compressors, and motor-driven tools.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1fctas9\" data-start=\"3941\" data-end=\"3965\"\u003e458cc PREDATOR Engine\u003c\/h2\u003e\n\u003cp data-start=\"3967\" data-end=\"4115\"\u003eThe generator is powered by a 458cc PREDATOR four-stroke gasoline engine engineered to provide the torque required for high-output power generation.\u003c\/p\u003e\n\u003cp data-start=\"4117\" data-end=\"4426\"\u003eIts electronic engine throttle automatically adjusts performance to help maintain stable output as electrical demand changes. The throttle system works with the digital automatic voltage regulator to support consistent voltage delivery for connected tools and appliances.\u003c\/p\u003e\n\u003cp data-start=\"4428\" data-end=\"4615\"\u003eThe engine includes an automatic choke system for easier push-button and remote starting. Under normal conditions, the operator does not need to manually adjust the choke before starting.\u003c\/p\u003e\n\u003cp data-start=\"4617\" data-end=\"4852\"\u003eA recoil starter is also included as a backup starting method. The manual choke override can be used if the electric-start battery does not have enough charge to operate the automatic choke system.\u003c\/p\u003e\n\u003ch2 data-section-id=\"2kclh7\" data-start=\"4854\" data-end=\"4893\"\u003eRemote, Electric and Recoil Starting\u003c\/h2\u003e\n\u003cp data-start=\"4895\" data-end=\"4969\"\u003eThe PREDATOR 13,000-Watt Tri-Fuel Generator offers three starting methods:\u003c\/p\u003e\n\u003cul data-start=\"4971\" data-end=\"5053\"\u003e\n\u003cli data-section-id=\"cxa50d\" data-start=\"4971\" data-end=\"4996\"\u003eRemote key-fob starting\u003c\/li\u003e\n\u003cli data-section-id=\"1on82ge\" data-start=\"4997\" data-end=\"5028\"\u003ePush-button electric starting\u003c\/li\u003e\n\u003cli data-section-id=\"1g7jm4s\" data-start=\"5029\" data-end=\"5053\"\u003eManual recoil starting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5055\" data-end=\"5299\"\u003eThe included remote control can start or stop the generator from up to approximately 100 feet away. Actual remote range may be reduced by walls, buildings, vehicles, interference, or a weak key-fob battery.\u003c\/p\u003e\n\u003cp data-start=\"5301\" data-end=\"5531\"\u003eRemote starting is convenient during a power outage because the generator can be started without walking directly to the unit, provided it has already been safely positioned outdoors, fueled, connected, and placed in standby mode.\u003c\/p\u003e\n\u003cp data-start=\"5533\" data-end=\"5722\"\u003eFor safety, remote start is disabled after a CO SECURE shutdown event until the engine has first been restarted using another approved starting method.\u003c\/p\u003e\n\u003cp data-start=\"5724\" data-end=\"6009\"\u003eThe remote uses a replaceable CR2032 battery. When the generator is placed in remote standby mode, it can normally be restarted remotely for up to 12 hours. After that period, the controller shuts down to conserve the generator’s starting battery.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cnsjbv\" data-start=\"6011\" data-end=\"6048\"\u003eCO SECURE Carbon-Monoxide Shutdown\u003c\/h2\u003e\n\u003cp data-start=\"6050\" data-end=\"6285\"\u003eCO SECURE technology continuously monitors the area around the generator for unsafe carbon-monoxide accumulation. If dangerous levels are detected, the system automatically shuts down the engine.\u003c\/p\u003e\n\u003cp data-start=\"6287\" data-end=\"6538\"\u003eThe generator complies with the ANSI\/PGMA G300 portable-generator safety standard. Its carbon-monoxide shutdown system is an additional protective feature, but it does not make indoor or enclosed operation safe.\u003c\/p\u003e\n\u003cp data-start=\"6540\" data-end=\"6730\"\u003eThe generator must only be operated outdoors, far away from occupied buildings, doors, windows, vents, garages, sheds, basements, crawlspaces, and other enclosed or partially enclosed areas.\u003c\/p\u003e\n\u003cp data-start=\"6732\" data-end=\"6758\"\u003eIt must never be operated:\u003c\/p\u003e\n\u003cul data-start=\"6760\" data-end=\"6964\"\u003e\n\u003cli data-section-id=\"i9r3zu\" data-start=\"6760\" data-end=\"6775\"\u003eInside a home\u003c\/li\u003e\n\u003cli data-section-id=\"58k85e\" data-start=\"6776\" data-end=\"6793\"\u003eInside a garage\u003c\/li\u003e\n\u003cli data-section-id=\"i9ecpb\" data-start=\"6794\" data-end=\"6809\"\u003eInside a shed\u003c\/li\u003e\n\u003cli data-section-id=\"wmia89\" data-start=\"6810\" data-end=\"6825\"\u003eIn a basement\u003c\/li\u003e\n\u003cli data-section-id=\"s3umxc\" data-start=\"6826\" data-end=\"6851\"\u003eUnder an enclosed porch\u003c\/li\u003e\n\u003cli data-section-id=\"1eq7szk\" data-start=\"6852\" data-end=\"6870\"\u003eInside a trailer\u003c\/li\u003e\n\u003cli data-section-id=\"1le8tau\" data-start=\"6871\" data-end=\"6903\"\u003eClose to open doors or windows\u003c\/li\u003e\n\u003cli data-section-id=\"9k6obr\" data-start=\"6904\" data-end=\"6964\"\u003eIn any area where exhaust could enter an occupied building\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6966\" data-end=\"7154\"\u003eCarbon monoxide is colorless and odorless. The generator’s sensor should never be used as a substitute for correct outdoor placement and working carbon-monoxide alarms inside the building.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1jpqj3o\" data-start=\"7156\" data-end=\"7195\"\u003eDigital Automatic Voltage Regulation\u003c\/h2\u003e\n\u003cp data-start=\"7197\" data-end=\"7303\"\u003eA digital automatic voltage regulator helps maintain stable electrical output when connected loads change.\u003c\/p\u003e\n\u003cp data-start=\"7305\" data-end=\"7599\"\u003eStable voltage is important for refrigerators, freezers, pumps, furnace components, lighting, power tools, and other electrical equipment. The regulator helps reduce excessive voltage fluctuations, but this is a conventional open-frame generator rather than a low-distortion inverter generator.\u003c\/p\u003e\n\u003cp data-start=\"7601\" data-end=\"7735\"\u003eUsers should verify the power requirements and sensitivity of connected electronics before operating them from any portable generator.\u003c\/p\u003e\n\u003ch2 data-section-id=\"18jdjgm\" data-start=\"7737\" data-end=\"7766\"\u003eAutomatic Idle-Down System\u003c\/h2\u003e\n\u003cp data-start=\"7768\" data-end=\"8038\"\u003eThe automatic idle-down function reduces engine speed when no electrical load is detected. This can decrease fuel consumption, engine noise, and unnecessary engine wear during periods when connected equipment is not drawing power.\u003c\/p\u003e\n\u003cp data-start=\"8040\" data-end=\"8150\"\u003eWhen electrical demand returns, the electronic throttle increases engine speed to provide the required output.\u003c\/p\u003e\n\u003cp data-start=\"8152\" data-end=\"8442\"\u003eAutomatic idle-down may not be appropriate for every load. Equipment requiring immediate starting current may perform better when the generator is operating at normal governed speed. The operator should follow the generator manual and the instructions supplied with the connected equipment.\u003c\/p\u003e\n\u003ch2 data-section-id=\"8uaoqa\" data-start=\"8444\" data-end=\"8473\"\u003eIntegrated Digital Display\u003c\/h2\u003e\n\u003cp data-start=\"8475\" data-end=\"8588\"\u003eThe control panel includes a digital display that allows the operator to monitor important operating information.\u003c\/p\u003e\n\u003cp data-start=\"8590\" data-end=\"8611\"\u003eThe display provides:\u003c\/p\u003e\n\u003cul data-start=\"8613\" data-end=\"8674\"\u003e\n\u003cli data-section-id=\"bfq591\" data-start=\"8613\" data-end=\"8629\"\u003eOutput voltage\u003c\/li\u003e\n\u003cli data-section-id=\"1ri5xuq\" data-start=\"8630\" data-end=\"8652\"\u003eElectrical frequency\u003c\/li\u003e\n\u003cli data-section-id=\"14rg6gu\" data-start=\"8653\" data-end=\"8674\"\u003eTotal running hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"8676\" data-end=\"8856\"\u003eRuntime tracking helps owners follow the maintenance schedule for engine oil, the air filter, spark plug, fuel system, and other components.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1hjknq2\" data-start=\"8858\" data-end=\"8874\"\u003ePower Outlets\u003c\/h2\u003e\n\u003cp data-start=\"8876\" data-end=\"9014\"\u003eThe generator includes a comprehensive outlet panel for household backup, jobsite equipment, recreational vehicles, and high-demand tools.\u003c\/p\u003e\n\u003cp data-start=\"9016\" data-end=\"9041\"\u003eIncluded receptacles are:\u003c\/p\u003e\n\u003cul data-start=\"9043\" data-end=\"9200\"\u003e\n\u003cli data-section-id=\"1lo8iiv\" data-start=\"9043\" data-end=\"9083\"\u003eFour 120V 5-20R GFCI-protected outlets\u003c\/li\u003e\n\u003cli data-section-id=\"1vnl6xg\" data-start=\"9084\" data-end=\"9119\"\u003eOne 120V L5-30R twist-lock outlet\u003c\/li\u003e\n\u003cli data-section-id=\"krikcd\" data-start=\"9120\" data-end=\"9160\"\u003eOne 120\/240V L14-30R twist-lock outlet\u003c\/li\u003e\n\u003cli data-section-id=\"1n7vfke\" data-start=\"9161\" data-end=\"9200\"\u003eOne 120\/240V 14-50R heavy-duty outlet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"9202\" data-end=\"9418\"\u003eThe four standard 120V outlets are arranged as two duplex receptacles. GFCI protection improves jobsite safety by disconnecting power when a ground-fault condition is detected.\u003c\/p\u003e\n\u003cp data-start=\"9420\" data-end=\"9581\"\u003eThe 30-amp and 50-amp 120\/240V outlets can support compatible transfer equipment, power-inlet systems, recreational vehicles, and higher-demand electrical loads.\u003c\/p\u003e\n\u003cp data-start=\"9583\" data-end=\"9866\"\u003eThe generator should never be connected directly to household wiring through an improvised cord or a standard wall outlet. Home-backup use requires a properly installed transfer switch or approved interlock and inlet system completed in accordance with local electrical requirements.\u003c\/p\u003e\n\u003ch2 data-section-id=\"nzw9rt\" data-start=\"9868\" data-end=\"9893\"\u003eHome-Backup Capability\u003c\/h2\u003e\n\u003cp data-start=\"9895\" data-end=\"10061\"\u003eThe 120\/240V output and 30-amp and 50-amp receptacles make the generator suitable for properly configured home-backup systems.\u003c\/p\u003e\n\u003cp data-start=\"10063\" data-end=\"10141\"\u003eDepending on the selected fuel and total load, it may support combinations of:\u003c\/p\u003e\n\u003cul data-start=\"10143\" data-end=\"10370\"\u003e\n\u003cli data-section-id=\"18r9k89\" data-start=\"10143\" data-end=\"10158\"\u003eRefrigerators\u003c\/li\u003e\n\u003cli data-section-id=\"ts5vky\" data-start=\"10159\" data-end=\"10169\"\u003eFreezers\u003c\/li\u003e\n\u003cli data-section-id=\"1v2c386\" data-start=\"10170\" data-end=\"10189\"\u003eLighting circuits\u003c\/li\u003e\n\u003cli data-section-id=\"1jvzp5\" data-start=\"10190\" data-end=\"10210\"\u003eInternet equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1tz898e\" data-start=\"10211\" data-end=\"10233\"\u003eTelevision equipment\u003c\/li\u003e\n\u003cli data-section-id=\"yxisya\" data-start=\"10234\" data-end=\"10251\"\u003eFurnace blowers\u003c\/li\u003e\n\u003cli data-section-id=\"fabl6g\" data-start=\"10252\" data-end=\"10264\"\u003eSump pumps\u003c\/li\u003e\n\u003cli data-section-id=\"2awyfl\" data-start=\"10265\" data-end=\"10277\"\u003eWell pumps\u003c\/li\u003e\n\u003cli data-section-id=\"2hnuy1\" data-start=\"10278\" data-end=\"10307\"\u003eSelected kitchen appliances\u003c\/li\u003e\n\u003cli data-section-id=\"17zqne1\" data-start=\"10308\" data-end=\"10333\"\u003eWindow air conditioners\u003c\/li\u003e\n\u003cli data-section-id=\"14atn7d\" data-start=\"10334\" data-end=\"10370\"\u003eOther essential household circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"10372\" data-end=\"10593\"\u003eIt should not be assumed that the generator can operate every circuit in a home simultaneously. A qualified electrician should calculate the expected running and starting loads and configure the backup system accordingly.\u003c\/p\u003e\n\u003cp data-start=\"10595\" data-end=\"10781\"\u003eCentral air-conditioning equipment, electric water heaters, electric ranges, clothes dryers, and large well pumps may require a significant portion of the generator’s available capacity.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1isiwvh\" data-start=\"10783\" data-end=\"10802\"\u003eGasoline Runtime\u003c\/h2\u003e\n\u003cp data-start=\"10804\" data-end=\"11138\"\u003eHarbor Freight rates the generator for more than 12 hours of runtime from one gasoline fill under the manufacturer’s specified operating conditions. This runtime figure applies to gasoline operation and will vary based on electrical load, engine condition, ambient temperature, and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"11140\" data-end=\"11170\"\u003eRuntime on propane depends on:\u003c\/p\u003e\n\u003cul data-start=\"11172\" data-end=\"11279\"\u003e\n\u003cli data-section-id=\"o99xvo\" data-start=\"11172\" data-end=\"11199\"\u003ePropane-cylinder capacity\u003c\/li\u003e\n\u003cli data-section-id=\"1wxya4g\" data-start=\"11200\" data-end=\"11217\"\u003eElectrical load\u003c\/li\u003e\n\u003cli data-section-id=\"1ah8124\" data-start=\"11218\" data-end=\"11239\"\u003eAmbient temperature\u003c\/li\u003e\n\u003cli data-section-id=\"1kz7ydz\" data-start=\"11240\" data-end=\"11255\"\u003eFuel pressure\u003c\/li\u003e\n\u003cli data-section-id=\"11acr5\" data-start=\"11256\" data-end=\"11279\"\u003eRegulator performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"11281\" data-end=\"11384\"\u003eRuntime on natural gas depends on the continuous availability and capacity of the connected gas supply.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1iy4e0u\" data-start=\"11386\" data-end=\"11405\"\u003eLow-Oil Shutdown\u003c\/h2\u003e\n\u003cp data-start=\"11407\" data-end=\"11553\"\u003eAn automatic low-oil shutdown system stops the engine if the oil level becomes too low for safe operation.\u003c\/p\u003e\n\u003cp data-start=\"11555\" data-end=\"11724\"\u003eThis feature helps protect the engine, but the oil level must still be checked before each use. The low-oil system should not replace regular inspection and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"11726\" data-end=\"11911\"\u003eThe generator is typically shipped without the required operating oil. The correct amount and grade of engine oil must be added before the first startup according to the owner’s manual.\u003c\/p\u003e\n\u003ch2 data-section-id=\"15dj3ry\" data-start=\"11913\" data-end=\"11937\"\u003eHeavy-Duty Open Frame\u003c\/h2\u003e\n\u003cp data-start=\"11939\" data-end=\"12195\"\u003eThe generator is protected by a heavy-duty 1.25-inch steel frame. The frame shields major components, provides convenient lifting and tie-down points, and supports the generator during transportation and jobsite use.\u003c\/p\u003e\n\u003cp data-start=\"12197\" data-end=\"12336\"\u003eThe open-frame construction improves cooling and service access but produces more operating noise than a fully enclosed inverter generator.\u003c\/p\u003e\n\u003ch2 data-section-id=\"s6ugit\" data-start=\"12338\" data-end=\"12366\"\u003eWheels and Folding Handle\u003c\/h2\u003e\n\u003cp data-start=\"12368\" data-end=\"12596\"\u003eTwo 10-inch flat-free wheels and a folding transport handle are included. These features make it easier to move the generator across driveways, garages, yards, and uneven jobsite surfaces.\u003c\/p\u003e\n\u003cp data-start=\"12598\" data-end=\"12831\"\u003eFlat-free wheels eliminate the need to maintain tire pressure. However, the generator is still a heavy machine and may require more than one person or suitable equipment when loading it into a truck or moving it across steep terrain.\u003c\/p\u003e\n\u003cp data-start=\"12833\" data-end=\"12927\"\u003eThe folding handle reduces the generator’s storage footprint when it is not being transported.\u003c\/p\u003e\n\u003ch2 data-section-id=\"41a5fq\" data-start=\"12929\" data-end=\"12951\"\u003eRoutine Maintenance\u003c\/h2\u003e\n\u003cp data-start=\"12953\" data-end=\"13078\"\u003eRegular maintenance is necessary to keep the engine, electrical system, fuel system, and safety features operating correctly.\u003c\/p\u003e\n\u003cp data-start=\"13080\" data-end=\"13101\"\u003eMaintenance includes:\u003c\/p\u003e\n\u003cul data-start=\"13103\" data-end=\"13663\"\u003e\n\u003cli data-section-id=\"cbvvvx\" data-start=\"13103\" data-end=\"13141\"\u003eChecking engine oil before every use\u003c\/li\u003e\n\u003cli data-section-id=\"1tq0t7q\" data-start=\"13142\" data-end=\"13189\"\u003eChanging engine oil at the required intervals\u003c\/li\u003e\n\u003cli data-section-id=\"1d6esjy\" data-start=\"13190\" data-end=\"13231\"\u003eInspecting and servicing the air filter\u003c\/li\u003e\n\u003cli data-section-id=\"1hj36eo\" data-start=\"13232\" data-end=\"13273\"\u003eInspecting and replacing the spark plug\u003c\/li\u003e\n\u003cli data-section-id=\"7w3ho1\" data-start=\"13274\" data-end=\"13303\"\u003eCleaning the spark arrestor\u003c\/li\u003e\n\u003cli data-section-id=\"h33j6t\" data-start=\"13304\" data-end=\"13338\"\u003eMaintaining the starting battery\u003c\/li\u003e\n\u003cli data-section-id=\"31j6zb\" data-start=\"13339\" data-end=\"13378\"\u003eInspecting fuel lines and connections\u003c\/li\u003e\n\u003cli data-section-id=\"1u5n0gl\" data-start=\"13379\" data-end=\"13435\"\u003eChecking propane and natural-gas connections for leaks\u003c\/li\u003e\n\u003cli data-section-id=\"1xi0sn7\" data-start=\"13436\" data-end=\"13485\"\u003eDraining or stabilizing gasoline before storage\u003c\/li\u003e\n\u003cli data-section-id=\"195zccu\" data-start=\"13486\" data-end=\"13526\"\u003eInspecting power cords and receptacles\u003c\/li\u003e\n\u003cli data-section-id=\"jc5ttn\" data-start=\"13527\" data-end=\"13572\"\u003eCleaning dirt and debris from cooling areas\u003c\/li\u003e\n\u003cli data-section-id=\"16m25ko\" data-start=\"13573\" data-end=\"13613\"\u003eTesting the CO SECURE indicator system\u003c\/li\u003e\n\u003cli data-section-id=\"51wah4\" data-start=\"13614\" data-end=\"13663\"\u003eMonitoring running hours on the digital display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"13665\" data-end=\"13855\"\u003eOnly fresh unleaded gasoline with an octane rating of 87 or higher should be used. The manual warns against gasoline containing more than 10% ethanol.\u003c\/p\u003e\n\u003cp data-start=\"13857\" data-end=\"13952\"\u003eThe generator should be allowed to cool before refueling, cleaning, transportation, or storage.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1cgu054\" data-start=\"13954\" data-end=\"13981\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"13983\" data-end=\"15900\"\u003e\n\u003cthead data-start=\"13983\" data-end=\"14010\"\u003e\n\u003ctr data-start=\"13983\" data-end=\"14010\"\u003e\n\u003cth class=\"last:pe-10\" data-start=\"13983\" data-end=\"13999\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-start=\"13999\" data-end=\"14010\" data-col-size=\"md\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"14025\" data-end=\"15900\"\u003e\n\u003ctr data-start=\"14025\" data-end=\"14045\"\u003e\n\u003ctd data-start=\"14025\" data-end=\"14033\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"14033\" data-end=\"14045\" data-col-size=\"md\"\u003ePREDATOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14046\" data-end=\"14103\"\u003e\n\u003ctd data-start=\"14046\" data-end=\"14061\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"14061\" data-end=\"14103\" data-col-size=\"md\"\u003eOpen-Frame Tri-Fuel Portable Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14104\" data-end=\"14135\"\u003e\n\u003ctd data-start=\"14104\" data-end=\"14126\" data-col-size=\"sm\"\u003ePrimary Item Number\u003c\/td\u003e\n\u003ctd data-start=\"14126\" data-end=\"14135\" data-col-size=\"md\"\u003e71386\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14136\" data-end=\"14170\"\u003e\n\u003ctd data-start=\"14136\" data-end=\"14161\" data-col-size=\"sm\"\u003eAdditional Item Number\u003c\/td\u003e\n\u003ctd data-start=\"14161\" data-end=\"14170\" data-col-size=\"md\"\u003e70476\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14171\" data-end=\"14208\"\u003e\n\u003ctd data-start=\"14171\" data-end=\"14199\" data-col-size=\"sm\"\u003eCalifornia-Compliant Item\u003c\/td\u003e\n\u003ctd data-start=\"14199\" data-end=\"14208\" data-col-size=\"md\"\u003e72860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14209\" data-end=\"14236\"\u003e\n\u003ctd data-start=\"14209\" data-end=\"14224\" data-col-size=\"sm\"\u003eEngine Brand\u003c\/td\u003e\n\u003ctd data-start=\"14224\" data-end=\"14236\" data-col-size=\"md\"\u003ePREDATOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14237\" data-end=\"14268\"\u003e\n\u003ctd data-start=\"14237\" data-end=\"14259\" data-col-size=\"sm\"\u003eEngine Displacement\u003c\/td\u003e\n\u003ctd data-start=\"14259\" data-end=\"14268\" data-col-size=\"md\"\u003e458cc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14269\" data-end=\"14314\"\u003e\n\u003ctd data-start=\"14269\" data-end=\"14283\" data-col-size=\"sm\"\u003eEngine Type\u003c\/td\u003e\n\u003ctd data-start=\"14283\" data-end=\"14314\" data-col-size=\"md\"\u003eFour-Stroke Gasoline Engine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14315\" data-end=\"14367\"\u003e\n\u003ctd data-start=\"14315\" data-end=\"14330\" data-col-size=\"sm\"\u003eFuel Options\u003c\/td\u003e\n\u003ctd data-start=\"14330\" data-end=\"14367\" data-col-size=\"md\"\u003eGasoline, Propane and Natural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14368\" data-end=\"14410\"\u003e\n\u003ctd data-start=\"14368\" data-end=\"14394\" data-col-size=\"sm\"\u003eGasoline Starting Watts\u003c\/td\u003e\n\u003ctd data-start=\"14394\" data-end=\"14410\" data-col-size=\"md\"\u003e13,000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14411\" data-end=\"14452\"\u003e\n\u003ctd data-start=\"14411\" data-end=\"14436\" data-col-size=\"sm\"\u003eGasoline Running Watts\u003c\/td\u003e\n\u003ctd data-start=\"14436\" data-end=\"14452\" data-col-size=\"md\"\u003e10,000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14453\" data-end=\"14494\"\u003e\n\u003ctd data-start=\"14453\" data-end=\"14478\" data-col-size=\"sm\"\u003ePropane Starting Watts\u003c\/td\u003e\n\u003ctd data-start=\"14478\" data-end=\"14494\" data-col-size=\"md\"\u003e12,000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14495\" data-end=\"14534\"\u003e\n\u003ctd data-start=\"14495\" data-end=\"14519\" data-col-size=\"sm\"\u003ePropane Running Watts\u003c\/td\u003e\n\u003ctd data-start=\"14519\" data-end=\"14534\" data-col-size=\"md\"\u003e9,100 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14535\" data-end=\"14580\"\u003e\n\u003ctd data-start=\"14535\" data-end=\"14564\" data-col-size=\"sm\"\u003eNatural-Gas Starting Watts\u003c\/td\u003e\n\u003ctd data-start=\"14564\" data-end=\"14580\" data-col-size=\"md\"\u003e10,000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14581\" data-end=\"14624\"\u003e\n\u003ctd data-start=\"14581\" data-end=\"14609\" data-col-size=\"sm\"\u003eNatural-Gas Running Watts\u003c\/td\u003e\n\u003ctd data-start=\"14609\" data-end=\"14624\" data-col-size=\"md\"\u003e7,800 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14625\" data-end=\"14655\"\u003e\n\u003ctd data-start=\"14625\" data-end=\"14642\" data-col-size=\"sm\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd data-start=\"14642\" data-end=\"14655\" data-col-size=\"md\"\u003e120V\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14656\" data-end=\"14718\"\u003e\n\u003ctd data-start=\"14656\" data-end=\"14675\" data-col-size=\"sm\"\u003eStarting Methods\u003c\/td\u003e\n\u003ctd data-start=\"14675\" data-end=\"14718\" data-col-size=\"md\"\u003eRemote, Push-Button Electric and Recoil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14719\" data-end=\"14776\"\u003e\n\u003ctd data-start=\"14719\" data-end=\"14744\" data-col-size=\"sm\"\u003eRemote Operating Range\u003c\/td\u003e\n\u003ctd data-start=\"14744\" data-end=\"14776\" data-col-size=\"md\"\u003eUp to Approximately 100 Feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14777\" data-end=\"14802\"\u003e\n\u003ctd data-start=\"14777\" data-end=\"14795\" data-col-size=\"sm\"\u003eAutomatic Choke\u003c\/td\u003e\n\u003ctd data-start=\"14795\" data-end=\"14802\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14803\" data-end=\"14845\"\u003e\n\u003ctd data-start=\"14803\" data-end=\"14819\" data-col-size=\"sm\"\u003eFuel Selector\u003c\/td\u003e\n\u003ctd data-start=\"14819\" data-end=\"14845\" data-col-size=\"md\"\u003eFour-Position Selector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14846\" data-end=\"14910\"\u003e\n\u003ctd data-start=\"14846\" data-end=\"14865\" data-col-size=\"sm\"\u003eGasoline Runtime\u003c\/td\u003e\n\u003ctd data-start=\"14865\" data-end=\"14910\" data-col-size=\"md\"\u003eMore Than 12 Hours Under Rated Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14911\" data-end=\"14971\"\u003e\n\u003ctd data-start=\"14911\" data-end=\"14932\" data-col-size=\"sm\"\u003eVoltage Regulation\u003c\/td\u003e\n\u003ctd data-start=\"14932\" data-end=\"14971\" data-col-size=\"md\"\u003eDigital Automatic Voltage Regulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"14972\" data-end=\"15001\"\u003e\n\u003ctd data-start=\"14972\" data-end=\"14994\" data-col-size=\"sm\"\u003eElectronic Throttle\u003c\/td\u003e\n\u003ctd data-start=\"14994\" data-end=\"15001\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15002\" data-end=\"15031\"\u003e\n\u003ctd data-start=\"15002\" data-end=\"15024\" data-col-size=\"sm\"\u003eAutomatic Idle-Down\u003c\/td\u003e\n\u003ctd data-start=\"15024\" data-end=\"15031\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15032\" data-end=\"15058\"\u003e\n\u003ctd data-start=\"15032\" data-end=\"15051\" data-col-size=\"sm\"\u003eLow-Oil Shutdown\u003c\/td\u003e\n\u003ctd data-start=\"15051\" data-end=\"15058\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15059\" data-end=\"15120\"\u003e\n\u003ctd data-start=\"15059\" data-end=\"15088\" data-col-size=\"sm\"\u003eCarbon-Monoxide Protection\u003c\/td\u003e\n\u003ctd data-start=\"15088\" data-end=\"15120\" data-col-size=\"md\"\u003eCO SECURE Automatic Shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15121\" data-end=\"15179\"\u003e\n\u003ctd data-start=\"15121\" data-end=\"15139\" data-col-size=\"sm\"\u003eDigital Display\u003c\/td\u003e\n\u003ctd data-start=\"15139\" data-end=\"15179\" data-col-size=\"md\"\u003eVoltage, Frequency and Running Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15180\" data-end=\"15245\"\u003e\n\u003ctd data-start=\"15180\" data-end=\"15204\" data-col-size=\"sm\"\u003eStandard 120V Outlets\u003c\/td\u003e\n\u003ctd data-start=\"15204\" data-end=\"15245\" data-col-size=\"md\"\u003eFour 5-20R GFCI-Protected Receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15246\" data-end=\"15289\"\u003e\n\u003ctd data-start=\"15246\" data-end=\"15264\" data-col-size=\"sm\"\u003e120V 30A Outlet\u003c\/td\u003e\n\u003ctd data-start=\"15264\" data-end=\"15289\" data-col-size=\"md\"\u003eOne L5-30R Twist Lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15290\" data-end=\"15338\"\u003e\n\u003ctd data-start=\"15290\" data-end=\"15312\" data-col-size=\"sm\"\u003e120\/240V 30A Outlet\u003c\/td\u003e\n\u003ctd data-start=\"15312\" data-end=\"15338\" data-col-size=\"md\"\u003eOne L14-30R Twist Lock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15339\" data-end=\"15393\"\u003e\n\u003ctd data-start=\"15339\" data-end=\"15361\" data-col-size=\"sm\"\u003e120\/240V 50A Outlet\u003c\/td\u003e\n\u003ctd data-start=\"15361\" data-end=\"15393\" data-col-size=\"md\"\u003eOne 14-50R Heavy-Duty Outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15394\" data-end=\"15419\"\u003e\n\u003ctd data-start=\"15394\" data-end=\"15412\" data-col-size=\"sm\"\u003eGFCI Protection\u003c\/td\u003e\n\u003ctd data-start=\"15412\" data-end=\"15419\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15420\" data-end=\"15452\"\u003e\n\u003ctd data-start=\"15420\" data-end=\"15445\" data-col-size=\"sm\"\u003eOSHA-Compliant Outlets\u003c\/td\u003e\n\u003ctd data-start=\"15445\" data-end=\"15452\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15453\" data-end=\"15489\"\u003e\n\u003ctd data-start=\"15453\" data-end=\"15471\" data-col-size=\"sm\"\u003eSafety Standard\u003c\/td\u003e\n\u003ctd data-start=\"15471\" data-end=\"15489\" data-col-size=\"md\"\u003eANSI\/PGMA G300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15490\" data-end=\"15528\"\u003e\n\u003ctd data-start=\"15490\" data-end=\"15498\" data-col-size=\"sm\"\u003eFrame\u003c\/td\u003e\n\u003ctd data-start=\"15498\" data-end=\"15528\" data-col-size=\"md\"\u003eHeavy-Duty 1.25-Inch Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15529\" data-end=\"15570\"\u003e\n\u003ctd data-start=\"15529\" data-end=\"15538\" data-col-size=\"sm\"\u003eWheels\u003c\/td\u003e\n\u003ctd data-start=\"15538\" data-end=\"15570\" data-col-size=\"md\"\u003eTwo 10-Inch Flat-Free Wheels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15571\" data-end=\"15601\"\u003e\n\u003ctd data-start=\"15571\" data-end=\"15590\" data-col-size=\"sm\"\u003eTransport Handle\u003c\/td\u003e\n\u003ctd data-start=\"15590\" data-end=\"15601\" data-col-size=\"md\"\u003eFolding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15602\" data-end=\"15633\"\u003e\n\u003ctd data-start=\"15602\" data-end=\"15621\" data-col-size=\"sm\"\u003eStarting Battery\u003c\/td\u003e\n\u003ctd data-start=\"15621\" data-end=\"15633\" data-col-size=\"md\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15634\" data-end=\"15663\"\u003e\n\u003ctd data-start=\"15634\" data-end=\"15651\" data-col-size=\"sm\"\u003eRemote Key Fob\u003c\/td\u003e\n\u003ctd data-start=\"15651\" data-end=\"15663\" data-col-size=\"md\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15664\" data-end=\"15702\"\u003e\n\u003ctd data-start=\"15664\" data-end=\"15685\" data-col-size=\"sm\"\u003ePropane Connection\u003c\/td\u003e\n\u003ctd data-start=\"15685\" data-end=\"15702\" data-col-size=\"md\"\u003eQuick Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15703\" data-end=\"15745\"\u003e\n\u003ctd data-start=\"15703\" data-end=\"15728\" data-col-size=\"sm\"\u003eNatural-Gas Connection\u003c\/td\u003e\n\u003ctd data-start=\"15728\" data-end=\"15745\" data-col-size=\"md\"\u003eQuick Connect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15746\" data-end=\"15784\"\u003e\n\u003ctd data-start=\"15746\" data-end=\"15765\" data-col-size=\"sm\"\u003eNatural-Gas Hose\u003c\/td\u003e\n\u003ctd data-start=\"15765\" data-end=\"15784\" data-col-size=\"md\"\u003eSold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15785\" data-end=\"15852\"\u003e\n\u003ctd data-start=\"15785\" data-end=\"15803\" data-col-size=\"sm\"\u003eRecommended Use\u003c\/td\u003e\n\u003ctd data-start=\"15803\" data-end=\"15852\" data-col-size=\"md\"\u003eHome Backup, Jobsites, Events and Emergencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"15853\" data-end=\"15900\"\u003e\n\u003ctd data-start=\"15853\" data-end=\"15870\" data-col-size=\"sm\"\u003eGenerator Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"15870\" data-end=\"15900\"\u003eConventional, Non-Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"15902\" data-end=\"16159\"\u003eThe fuel-specific power ratings are taken from the official owner’s manual, while the outlets, engine, remote range, safety system, and operating features are confirmed by Harbor Freight’s current product information.\u003c\/p\u003e\n\u003ch2 data-section-id=\"xydb7h\" data-start=\"16161\" data-end=\"16179\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-start=\"16181\" data-end=\"16775\"\u003e\n\u003cli data-section-id=\"g4u3d9\" data-start=\"16181\" data-end=\"16222\"\u003ePREDATOR 13,000-Watt tri-fuel generator\u003c\/li\u003e\n\u003cli data-section-id=\"o8lc5w\" data-start=\"16223\" data-end=\"16246\"\u003e458cc PREDATOR engine\u003c\/li\u003e\n\u003cli data-section-id=\"51vxk1\" data-start=\"16247\" data-end=\"16278\"\u003eIntegrated gasoline fuel tank\u003c\/li\u003e\n\u003cli data-section-id=\"mq7jta\" data-start=\"16279\" data-end=\"16325\"\u003ePropane and natural-gas quick-connect system\u003c\/li\u003e\n\u003cli data-section-id=\"di3wi6\" data-start=\"16326\" data-end=\"16352\"\u003eElectric starting system\u003c\/li\u003e\n\u003cli data-section-id=\"1ljnfff\" data-start=\"16353\" data-end=\"16376\"\u003eManual recoil starter\u003c\/li\u003e\n\u003cli data-section-id=\"wb9cyt\" data-start=\"16377\" data-end=\"16395\"\u003eStarting battery\u003c\/li\u003e\n\u003cli data-section-id=\"uwcrxf\" data-start=\"16396\" data-end=\"16427\"\u003eRemote start and stop key fob\u003c\/li\u003e\n\u003cli data-section-id=\"111rm4v\" data-start=\"16428\" data-end=\"16462\"\u003eFour 120V GFCI-protected outlets\u003c\/li\u003e\n\u003cli data-section-id=\"1r6kxx3\" data-start=\"16463\" data-end=\"16491\"\u003e120V 30A twist-lock outlet\u003c\/li\u003e\n\u003cli data-section-id=\"v8l6i6\" data-start=\"16492\" data-end=\"16524\"\u003e120\/240V 30A twist-lock outlet\u003c\/li\u003e\n\u003cli data-section-id=\"1sywiub\" data-start=\"16525\" data-end=\"16546\"\u003e120\/240V 50A outlet\u003c\/li\u003e\n\u003cli data-section-id=\"rl4q7n\" data-start=\"16547\" data-end=\"16590\"\u003eCO SECURE carbon-monoxide shutdown system\u003c\/li\u003e\n\u003cli data-section-id=\"19itxw5\" data-start=\"16591\" data-end=\"16639\"\u003eDigital voltage, frequency and runtime display\u003c\/li\u003e\n\u003cli data-section-id=\"4nfdd7\" data-start=\"16640\" data-end=\"16668\"\u003eAutomatic idle-down system\u003c\/li\u003e\n\u003cli data-section-id=\"1867p6q\" data-start=\"16669\" data-end=\"16699\"\u003eTwo 10-inch flat-free wheels\u003c\/li\u003e\n\u003cli data-section-id=\"1koo9nk\" data-start=\"16700\" data-end=\"16726\"\u003eFolding transport handle\u003c\/li\u003e\n\u003cli data-section-id=\"qs98ss\" data-start=\"16727\" data-end=\"16751\"\u003eHeavy-duty steel frame\u003c\/li\u003e\n\u003cli data-section-id=\"fyzdm9\" data-start=\"16752\" data-end=\"16775\"\u003eOwner’s documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"16777\" data-end=\"16954\"\u003eEngine oil, transfer equipment, extension cords, propane cylinder, natural-gas hose, and home electrical connections may not be included and should be confirmed before purchase.\u003c\/p\u003e\n\u003ch2 data-section-id=\"5x5wsn\" data-start=\"16956\" data-end=\"16986\"\u003eAccessories Sold Separately\u003c\/h2\u003e\n\u003cul data-start=\"16988\" data-end=\"17531\"\u003e\n\u003cli data-section-id=\"1ru45c8\" data-start=\"16988\" data-end=\"17014\"\u003e25-foot natural-gas hose\u003c\/li\u003e\n\u003cli data-section-id=\"1687xd0\" data-start=\"17015\" data-end=\"17048\"\u003eProperly rated propane cylinder\u003c\/li\u003e\n\u003cli data-section-id=\"1bp5nfd\" data-start=\"17049\" data-end=\"17087\"\u003eHeavy-duty generator extension cords\u003c\/li\u003e\n\u003cli data-section-id=\"s8ofoz\" data-start=\"17088\" data-end=\"17111\"\u003e30-amp generator cord\u003c\/li\u003e\n\u003cli data-section-id=\"wz416d\" data-start=\"17112\" data-end=\"17135\"\u003e50-amp generator cord\u003c\/li\u003e\n\u003cli data-section-id=\"1b2hu26\" data-start=\"17136\" data-end=\"17161\"\u003eOutdoor generator cover\u003c\/li\u003e\n\u003cli data-section-id=\"vqj22w\" data-start=\"17162\" data-end=\"17234\"\u003eWeather-resistant operating enclosure approved for portable generators\u003c\/li\u003e\n\u003cli data-section-id=\"1dtt81q\" data-start=\"17235\" data-end=\"17266\"\u003eBattery charger or maintainer\u003c\/li\u003e\n\u003cli data-section-id=\"r0wklb\" data-start=\"17267\" data-end=\"17295\"\u003eReplacement remote battery\u003c\/li\u003e\n\u003cli data-section-id=\"asf32p\" data-start=\"17296\" data-end=\"17313\"\u003eTransfer switch\u003c\/li\u003e\n\u003cli data-section-id=\"19oi4im\" data-start=\"17314\" data-end=\"17345\"\u003eGenerator interlock equipment\u003c\/li\u003e\n\u003cli data-section-id=\"1t2n1vx\" data-start=\"17346\" data-end=\"17371\"\u003eOutdoor power-inlet box\u003c\/li\u003e\n\u003cli data-section-id=\"gmu4c8\" data-start=\"17372\" data-end=\"17413\"\u003eWheel and handle replacement components\u003c\/li\u003e\n\u003cli data-section-id=\"tva1v0\" data-start=\"17414\" data-end=\"17426\"\u003eEngine oil\u003c\/li\u003e\n\u003cli data-section-id=\"dxyfhw\" data-start=\"17427\" data-end=\"17450\"\u003eOil drain accessories\u003c\/li\u003e\n\u003cli data-section-id=\"1sb3gy\" data-start=\"17451\" data-end=\"17463\"\u003eAir filter\u003c\/li\u003e\n\u003cli data-section-id=\"8ebwpp\" data-start=\"17464\" data-end=\"17476\"\u003eSpark plug\u003c\/li\u003e\n\u003cli data-section-id=\"a1n4mv\" data-start=\"17477\" data-end=\"17494\"\u003eFuel stabilizer\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5fhf\" data-start=\"17495\" data-end=\"17531\"\u003eGrounding equipment where required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"17533\" data-end=\"17697\"\u003eTransfer switches, interlocks, inlet boxes, gas connections, and other permanent home-backup components should be selected and installed by qualified professionals.\u003c\/p\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"17699\" data-end=\"17720\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cul data-start=\"17722\" data-end=\"18320\"\u003e\n\u003cli data-section-id=\"1u25xa8\" data-start=\"17722\" data-end=\"17745\"\u003eEmergency home backup\u003c\/li\u003e\n\u003cli data-section-id=\"1q7toiu\" data-start=\"17746\" data-end=\"17779\"\u003eRefrigerator and freezer backup\u003c\/li\u003e\n\u003cli data-section-id=\"1tdqemr\" data-start=\"17780\" data-end=\"17801\"\u003eSump-pump operation\u003c\/li\u003e\n\u003cli data-section-id=\"16wlazl\" data-start=\"17802\" data-end=\"17820\"\u003eWell-pump backup\u003c\/li\u003e\n\u003cli data-section-id=\"odj7g9\" data-start=\"17821\" data-end=\"17847\"\u003eFurnace-blower operation\u003c\/li\u003e\n\u003cli data-section-id=\"7oxmj4\" data-start=\"17848\" data-end=\"17881\"\u003eSelected air-conditioning loads\u003c\/li\u003e\n\u003cli data-section-id=\"1m6wr7r\" data-start=\"17882\" data-end=\"17902\"\u003eWorkshop equipment\u003c\/li\u003e\n\u003cli data-section-id=\"zd3ylm\" data-start=\"17903\" data-end=\"17926\"\u003eConstruction jobsites\u003c\/li\u003e\n\u003cli data-section-id=\"ii1mvs\" data-start=\"17927\" data-end=\"17952\"\u003eHigh-demand power tools\u003c\/li\u003e\n\u003cli data-section-id=\"k3ai8f\" data-start=\"17953\" data-end=\"17969\"\u003eOutdoor events\u003c\/li\u003e\n\u003cli data-section-id=\"j2a581\" data-start=\"17970\" data-end=\"17998\"\u003eRecreational-vehicle power\u003c\/li\u003e\n\u003cli data-section-id=\"1uej6v5\" data-start=\"17999\" data-end=\"18030\"\u003eFarm and property maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"12lwo39\" data-start=\"18031\" data-end=\"18065\"\u003eAreas with access to natural gas\u003c\/li\u003e\n\u003cli data-section-id=\"155saiw\" data-start=\"18066\" data-end=\"18103\"\u003eUsers requiring propane flexibility\u003c\/li\u003e\n\u003cli data-section-id=\"weow6m\" data-start=\"18104\" data-end=\"18128\"\u003eExtended power outages\u003c\/li\u003e\n\u003cli data-section-id=\"8mv4ag\" data-start=\"18129\" data-end=\"18174\"\u003eApplications requiring 120V and 240V output\u003c\/li\u003e\n\u003cli data-section-id=\"x0xy87\" data-start=\"18175\" data-end=\"18205\"\u003eUsers wanting remote startup\u003c\/li\u003e\n\u003cli data-section-id=\"1qoolld\" data-start=\"18206\" data-end=\"18258\"\u003eProperties requiring a 50-amp generator connection\u003c\/li\u003e\n\u003cli data-section-id=\"oym2ch\" data-start=\"18259\" data-end=\"18320\"\u003eSituations where multiple fuel options improve availability\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Northroot","offers":[{"title":"Default Title","offer_id":43743217844314,"sku":null,"price":680.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0751\/0366\/6266\/files\/main-image.jpg?v=1785187628","url":"https:\/\/checkout.northroot.shop\/products\/predator-13000-watt-tri-fuel-portable-generator-with-remote-start-and-co-secure-technology","provider":"Northroot","version":"1.0","type":"link"}